Session
Civil Engineering, Infrastructure and Environment
Description
Fiber reinforced polymer (FRP) composites (the combination of two or more materials). The strengthening of concrete members means using constructional measures to restore or improve their load-carrying capacity, serviceability, durability or fatigue strength.
The effects of strengthening measures can generally be described in quantitative terms and therefore analyzed numerically for reinforced concrete columns designed according to the earlier editions of DIN 1045, ACI Committee 440, 2002, there are some strengthening assignments that fall midway between redesign and sprayed concrete. It is for these projects that wrapping with fiber-reinforced materials is to be recommended. This method has already been used frequently in Europe and elsewhere, often on the basis of design codes or guides covering the subsequent strengthening of reinforced concrete compression members by means of wrapping with fiber-reinforced materials. This paper presents an example for strengthening the reinforced concrete column a wrapping of CF sheet externally
Keywords:
Composite, CF sheets, reinforced concrete columns, wrapping, strengthening
Proceedings Editor
Edmond Hajrizi
ISBN
978-9951-437-50-9
First Page
23
Last Page
31
Location
Durres, Albania
Start Date
28-10-2016 9:00 AM
End Date
30-10-2016 5:00 PM
DOI
10.33107/ubt-ic.2016.11
Recommended Citation
Istrefi, Florim, "Strengthening the reinforced concrete column with CF sheet" (2016). UBT International Conference. 11.
https://knowledgecenter.ubt-uni.net/conference/2016/all-events/11
Included in
Strengthening the reinforced concrete column with CF sheet
Durres, Albania
Fiber reinforced polymer (FRP) composites (the combination of two or more materials). The strengthening of concrete members means using constructional measures to restore or improve their load-carrying capacity, serviceability, durability or fatigue strength.
The effects of strengthening measures can generally be described in quantitative terms and therefore analyzed numerically for reinforced concrete columns designed according to the earlier editions of DIN 1045, ACI Committee 440, 2002, there are some strengthening assignments that fall midway between redesign and sprayed concrete. It is for these projects that wrapping with fiber-reinforced materials is to be recommended. This method has already been used frequently in Europe and elsewhere, often on the basis of design codes or guides covering the subsequent strengthening of reinforced concrete compression members by means of wrapping with fiber-reinforced materials. This paper presents an example for strengthening the reinforced concrete column a wrapping of CF sheet externally