Comparative Control of the Construction Accuracy of the Seven Floor Building with the Structural Design

Session

Civil Engineering, Infrastructure and Environment

Description

In the framework of quality implementation criteria during the construction of multi-story buildings in the capital of Kosovo, Prishtina, among others, it is required that in the structural design phase to control inter-story drifts, respectively to determine whether the P-delta effect should be taken into account during the structural design. In addition, in the framework of the criteria for quality control of the construction, it is foreseen the regular control of the accuracy of the verticality during the construction of the vertical structural elements (columns and diaphragm walls) which are ascertained with regular geodetic measurements in each floor level. In this paper, the authors present the research carried out by checking the vertical elements executed in a seven-story building built in Prishtina, then have presented a comparison between the designed and executed values of inter-story drifts. Through this research, the authors want to emphasize the importance of the accuracy of the realization of vertical elements, their precise control and if necessary to perform additional analytical control taking into account the vertical deviations during construction.

Keywords:

Verticality of structural elements, inter-story drifts, regular geodetic control, deviations during construction.

Proceedings Editor

Edmond Hajrizi

ISBN

978-9951-550-50-5

Location

UBT Kampus, Lipjan

Start Date

29-10-2022 12:00 AM

End Date

30-10-2022 12:00 AM

DOI

10.33107/ubt-ic.2022.214

This document is currently not available here.

Share

COinS
 
Oct 29th, 12:00 AM Oct 30th, 12:00 AM

Comparative Control of the Construction Accuracy of the Seven Floor Building with the Structural Design

UBT Kampus, Lipjan

In the framework of quality implementation criteria during the construction of multi-story buildings in the capital of Kosovo, Prishtina, among others, it is required that in the structural design phase to control inter-story drifts, respectively to determine whether the P-delta effect should be taken into account during the structural design. In addition, in the framework of the criteria for quality control of the construction, it is foreseen the regular control of the accuracy of the verticality during the construction of the vertical structural elements (columns and diaphragm walls) which are ascertained with regular geodetic measurements in each floor level. In this paper, the authors present the research carried out by checking the vertical elements executed in a seven-story building built in Prishtina, then have presented a comparison between the designed and executed values of inter-story drifts. Through this research, the authors want to emphasize the importance of the accuracy of the realization of vertical elements, their precise control and if necessary to perform additional analytical control taking into account the vertical deviations during construction.