Aim: The aim of this study is to demonstrate the adhesion of different posts fiber and zirconium, cemented with different cements Multilink Automix (MLA)- Ivoclar Vivadent, and RelyX Unicem 2 automix (RLX)-3M ESPE.

Material and method: For this study, we used two types of resin cements: Multilink Automix (MLA)- Ivoclar Vivadent, and RelyX Unicem 2 automix (RLX)-3 MESPE, 60 zirconium post and 60 fiber post with different diameter d1=1,2; d2=1,35 and d3=1,5 , and extracted incisors. Zirconium posts of different were applied in every sample and were cemented with two types of resin cements. The Pull-out test, was applied on the prepared samples. For the test we used Universal Testing Mashine, and maximum force was measured in newtons (N).

Results and discussion: the obtained results from the research show us that zirconium post systems and fiber post systems are increasingly used in everyday dental practice. The extraction power of zirconium posts cemented with RelyX Unicem 2 Automix cement showed the best results with diameter d3, compared to other diameters d1 and d2. The extraction power of fiber posts cemented with RelyX Unicem 2 Automix cement showed the best results with diameter d3, compared to other diameters d1 and d2. Conclusion: It is important that the applied resin cements play a special role in the retention and adhesion of the post system in the root part of the tooth.

Keywords:

Zirconium post, fiber post, resin cements.

Proceedings Editor

Edmond Hajrizi

ISBN

978-9951-550-47-5

Location

UBT Kampus, Lipjan

Start Date

30-10-2021 12:00 AM

End Date

30-10-2021 12:00 AM

DOI

10.33107/ubt-ic.2021.408

This document is currently not available here.

Share

COinS
 
Oct 30th, 12:00 AM Oct 30th, 12:00 AM

FIBER AND ZICONIUM POSTS AND ADHESION WITH DIFFERENT CEMENTS

UBT Kampus, Lipjan

Aim: The aim of this study is to demonstrate the adhesion of different posts fiber and zirconium, cemented with different cements Multilink Automix (MLA)- Ivoclar Vivadent, and RelyX Unicem 2 automix (RLX)-3M ESPE.

Material and method: For this study, we used two types of resin cements: Multilink Automix (MLA)- Ivoclar Vivadent, and RelyX Unicem 2 automix (RLX)-3 MESPE, 60 zirconium post and 60 fiber post with different diameter d1=1,2; d2=1,35 and d3=1,5 , and extracted incisors. Zirconium posts of different were applied in every sample and were cemented with two types of resin cements. The Pull-out test, was applied on the prepared samples. For the test we used Universal Testing Mashine, and maximum force was measured in newtons (N).

Results and discussion: the obtained results from the research show us that zirconium post systems and fiber post systems are increasingly used in everyday dental practice. The extraction power of zirconium posts cemented with RelyX Unicem 2 Automix cement showed the best results with diameter d3, compared to other diameters d1 and d2. The extraction power of fiber posts cemented with RelyX Unicem 2 Automix cement showed the best results with diameter d3, compared to other diameters d1 and d2. Conclusion: It is important that the applied resin cements play a special role in the retention and adhesion of the post system in the root part of the tooth.